Leo-Patch 1.6 · Q1HY MoDT · Observations 14 October 2026
Thermal
Pch Thermal Throttling Control
Pch Thermal Throttling Control firmware setup page decoded from AMI HII/IFR resources.
- Form ID
- 0x27ba
- Records
- 26
- Path
- Setup / Chipset / PCH-IO Configuration / Pch Thermal Throttling Control
Record 4596
Thermal Throttling Level
Firmware Value
Determine if use Intel suggested setting
- Opcode
- OneOf
- Question ID
- 0x10e3
- VarStore
- PchSetup
- VarStore GUID
- 4570B7F1-ADE8-4943-8DC3-406472842384
- Offset
- 0x717
- Width
- 1 byte(s)
- Range
- 0 to 1 step 0
Permalink
Record 4597
Thermal Throttling
Firmware Value
Enable/Disable the thermal throttling states control
- Opcode
- CheckBox
- Question ID
- 0x10e4
- VarStore
- PchSetup
- VarStore GUID
- 4570B7F1-ADE8-4943-8DC3-406472842384
- Offset
- 0x71e
Visibility / conditions
- {"condition_id": 1810, "type": "SuppressIf", "offset": 525023, "expr": ["EqIdVal QuestionId: 0x10E3, Value: 0x1"]}
Permalink
PMSync state 13 will force at least T2 state
- Opcode
- CheckBox
- Question ID
- 0x10e5
- VarStore
- PchSetup
- VarStore GUID
- 4570B7F1-ADE8-4943-8DC3-406472842384
- Offset
- 0x71f
Visibility / conditions
- {"condition_id": 1810, "type": "SuppressIf", "offset": 525023, "expr": ["EqIdVal QuestionId: 0x10E3, Value: 0x1"]}
Permalink
Record 4599
Thermal Throttling Lock
Firmware Value
Lock the entire TL register
- Opcode
- CheckBox
- Question ID
- 0x10e6
- VarStore
- PchSetup
- VarStore GUID
- 4570B7F1-ADE8-4943-8DC3-406472842384
- Offset
- 0x720
Visibility / conditions
- {"condition_id": 1810, "type": "SuppressIf", "offset": 525023, "expr": ["EqIdVal QuestionId: 0x10E3, Value: 0x1"]}
Permalink
If Trip Point Temperature <= T0Level, the system is in T0 state
- Opcode
- Numeric
- Question ID
- 0x10e7
- VarStore
- PchSetup
- VarStore GUID
- 4570B7F1-ADE8-4943-8DC3-406472842384
- Offset
- 0x718
- Width
- 2 byte(s)
- Range
- 0 to 65535 step 1
Visibility / conditions
- {"condition_id": 1810, "type": "SuppressIf", "offset": 525023, "expr": ["EqIdVal QuestionId: 0x10E3, Value: 0x1"]}
Permalink
If T1Level >= Trip Point Temperature > T0Level, the system is in T1 state
- Opcode
- Numeric
- Question ID
- 0x10e8
- VarStore
- PchSetup
- VarStore GUID
- 4570B7F1-ADE8-4943-8DC3-406472842384
- Offset
- 0x71a
- Width
- 2 byte(s)
- Range
- 0 to 65535 step 1
Visibility / conditions
- {"condition_id": 1810, "type": "SuppressIf", "offset": 525023, "expr": ["EqIdVal QuestionId: 0x10E3, Value: 0x1"]}
Permalink
If T2Level >= Trip Point Temperature > T1Level, the system is in T2 state
- Opcode
- Numeric
- Question ID
- 0x10e9
- VarStore
- PchSetup
- VarStore GUID
- 4570B7F1-ADE8-4943-8DC3-406472842384
- Offset
- 0x71c
- Width
- 2 byte(s)
- Range
- 0 to 65535 step 1
Visibility / conditions
- {"condition_id": 1810, "type": "SuppressIf", "offset": 525023, "expr": ["EqIdVal QuestionId: 0x10E3, Value: 0x1"]}
Permalink
Record 4603
DMI Thermal Setting
Firmware Value
Determine if use Intel suggested setting
- Opcode
- OneOf
- Question ID
- 0x10ea
- VarStore
- PchSetup
- VarStore GUID
- 4570B7F1-ADE8-4943-8DC3-406472842384
- Offset
- 0x721
- Width
- 1 byte(s)
- Range
- 0 to 1 step 0
Permalink
Record 4604
DMI Thermal Sensor Autonomous Width
Firmware Value
Enable/Disable Thermal Sensor initiated Autonomous Width Negotiation
- Opcode
- CheckBox
- Question ID
- 0x10eb
- VarStore
- PchSetup
- VarStore GUID
- 4570B7F1-ADE8-4943-8DC3-406472842384
- Offset
- 0x726
Visibility / conditions
- {"condition_id": 1811, "type": "SuppressIf", "offset": 525201, "expr": ["EqIdVal QuestionId: 0x10EA, Value: 0x1"]}
Permalink
Record 4605
Thermal Sensor 0 Width
Firmware Value
Determine the DMI Link Width when the output from the Thermal Sensor is T0
- Opcode
- OneOf
- Question ID
- 0x10ec
- VarStore
- PchSetup
- VarStore GUID
- 4570B7F1-ADE8-4943-8DC3-406472842384
- Offset
- 0x722
- Width
- 1 byte(s)
- Range
- 0 to 4 step 0
Visibility / conditions
- {"condition_id": 1811, "type": "SuppressIf", "offset": 525201, "expr": ["EqIdVal QuestionId: 0x10EA, Value: 0x1"]}
Permalink
Record 4606
Thermal Sensor 1 Width
Firmware Value
Determine the DMI Link Width when the output from the Thermal Sensor is T1
- Opcode
- OneOf
- Question ID
- 0x10ed
- VarStore
- PchSetup
- VarStore GUID
- 4570B7F1-ADE8-4943-8DC3-406472842384
- Offset
- 0x723
- Width
- 1 byte(s)
- Range
- 0 to 4 step 0
Visibility / conditions
- {"condition_id": 1811, "type": "SuppressIf", "offset": 525201, "expr": ["EqIdVal QuestionId: 0x10EA, Value: 0x1"]}
Permalink
Record 4607
Thermal Sensor 2 Width
Firmware Value
Determine the DMI Link Width when the output from the Thermal Sensor is T2
- Opcode
- OneOf
- Question ID
- 0x10ee
- VarStore
- PchSetup
- VarStore GUID
- 4570B7F1-ADE8-4943-8DC3-406472842384
- Offset
- 0x724
- Width
- 1 byte(s)
- Range
- 0 to 4 step 0
Visibility / conditions
- {"condition_id": 1811, "type": "SuppressIf", "offset": 525201, "expr": ["EqIdVal QuestionId: 0x10EA, Value: 0x1"]}
Permalink
Record 4608
Thermal Sensor 3 Width
Firmware Value
Determine the DMI Link Width when the output from the Thermal Sensor is T3
- Opcode
- OneOf
- Question ID
- 0x10ef
- VarStore
- PchSetup
- VarStore GUID
- 4570B7F1-ADE8-4943-8DC3-406472842384
- Offset
- 0x725
- Width
- 1 byte(s)
- Range
- 0 to 4 step 0
Visibility / conditions
- {"condition_id": 1811, "type": "SuppressIf", "offset": 525201, "expr": ["EqIdVal QuestionId: 0x10EA, Value: 0x1"]}
Permalink
Record 4609
SATA Thermal Setting
Firmware Value
Determine if use Intel suggested setting
- Opcode
- OneOf
- Question ID
- 0x10f0
- VarStore
- PchSetup
- VarStore GUID
- 4570B7F1-ADE8-4943-8DC3-406472842384
- Offset
- 0x727
- Width
- 1 byte(s)
- Range
- 0 to 1 step 0
Permalink
Determine the value of SATA Port T1 Multipler
- Opcode
- OneOf
- Question ID
- 0x10f1
- VarStore
- PchSetup
- VarStore GUID
- 4570B7F1-ADE8-4943-8DC3-406472842384
- Offset
- 0x728
- Width
- 1 byte(s)
- Range
- 0 to 3 step 0
Visibility / conditions
- {"condition_id": 1812, "type": "SuppressIf", "offset": 525476, "expr": ["EqIdVal QuestionId: 0x10F0, Value: 0x1"]}
Permalink
Determine the value of SATA Port T2 Multipler
- Opcode
- OneOf
- Question ID
- 0x10f2
- VarStore
- PchSetup
- VarStore GUID
- 4570B7F1-ADE8-4943-8DC3-406472842384
- Offset
- 0x729
- Width
- 1 byte(s)
- Range
- 0 to 3 step 0
Visibility / conditions
- {"condition_id": 1812, "type": "SuppressIf", "offset": 525476, "expr": ["EqIdVal QuestionId: 0x10F0, Value: 0x1"]}
Permalink
Determine the value of SATA Port T3 Multipler
- Opcode
- OneOf
- Question ID
- 0x10f3
- VarStore
- PchSetup
- VarStore GUID
- 4570B7F1-ADE8-4943-8DC3-406472842384
- Offset
- 0x72a
- Width
- 1 byte(s)
- Range
- 0 to 3 step 0
Visibility / conditions
- {"condition_id": 1812, "type": "SuppressIf", "offset": 525476, "expr": ["EqIdVal QuestionId: 0x10F0, Value: 0x1"]}
Permalink
Record 4613
Alternate Fast Init Tdispatch
Firmware Value
Enable/Disable SATA Port Alternate Fast Init Tdispatch
- Opcode
- CheckBox
- Question ID
- 0x10f4
- VarStore
- PchSetup
- VarStore GUID
- 4570B7F1-ADE8-4943-8DC3-406472842384
- Offset
- 0x72d
Visibility / conditions
- {"condition_id": 1812, "type": "SuppressIf", "offset": 525476, "expr": ["EqIdVal QuestionId: 0x10F0, Value: 0x1"]}
Permalink
Determine the value of SATA Port Tdispatch
- Opcode
- OneOf
- Question ID
- 0x10f5
- VarStore
- PchSetup
- VarStore GUID
- 4570B7F1-ADE8-4943-8DC3-406472842384
- Offset
- 0x72b
- Width
- 1 byte(s)
- Range
- 0 to 3 step 0
Visibility / conditions
- {"condition_id": 1813, "type": "SuppressIf", "offset": 525652, "expr": ["EqIdVal QuestionId: 0x10F0, Value: 0x1"]}
Permalink
Determine the value of SATA Port Tinactive
- Opcode
- OneOf
- Question ID
- 0x10f6
- VarStore
- PchSetup
- VarStore GUID
- 4570B7F1-ADE8-4943-8DC3-406472842384
- Offset
- 0x72c
- Width
- 1 byte(s)
- Range
- 0 to 3 step 0
Visibility / conditions
- {"condition_id": 1813, "type": "SuppressIf", "offset": 525652, "expr": ["EqIdVal QuestionId: 0x10F0, Value: 0x1"]}
Permalink
Determine the value of SATA Port T1 Multipler
- Opcode
- OneOf
- Question ID
- 0x10f7
- VarStore
- PchSetup
- VarStore GUID
- 4570B7F1-ADE8-4943-8DC3-406472842384
- Offset
- 0x72e
- Width
- 1 byte(s)
- Range
- 0 to 3 step 0
Visibility / conditions
- {"condition_id": 1818, "type": "SuppressIf", "offset": 525824, "expr": ["EqIdVal QuestionId: 0x10F0, Value: 0x1"]}
Permalink
Determine the value of SATA Port T2 Multipler
- Opcode
- OneOf
- Question ID
- 0x10f8
- VarStore
- PchSetup
- VarStore GUID
- 4570B7F1-ADE8-4943-8DC3-406472842384
- Offset
- 0x72f
- Width
- 1 byte(s)
- Range
- 0 to 3 step 0
Visibility / conditions
- {"condition_id": 1818, "type": "SuppressIf", "offset": 525824, "expr": ["EqIdVal QuestionId: 0x10F0, Value: 0x1"]}
Permalink
Determine the value of SATA Port T3 Multipler
- Opcode
- OneOf
- Question ID
- 0x10f9
- VarStore
- PchSetup
- VarStore GUID
- 4570B7F1-ADE8-4943-8DC3-406472842384
- Offset
- 0x730
- Width
- 1 byte(s)
- Range
- 0 to 3 step 0
Visibility / conditions
- {"condition_id": 1818, "type": "SuppressIf", "offset": 525824, "expr": ["EqIdVal QuestionId: 0x10F0, Value: 0x1"]}
Permalink
Record 4619
Alternate Fast Init Tdispatch
Firmware Value
Enable/Disable SATA Port Alternate Fast Init Tdispatch
- Opcode
- CheckBox
- Question ID
- 0x10fa
- VarStore
- PchSetup
- VarStore GUID
- 4570B7F1-ADE8-4943-8DC3-406472842384
- Offset
- 0x733
Visibility / conditions
- {"condition_id": 1818, "type": "SuppressIf", "offset": 525824, "expr": ["EqIdVal QuestionId: 0x10F0, Value: 0x1"]}
Permalink
Determine the value of SATA Port Tdispatch
- Opcode
- OneOf
- Question ID
- 0x10fb
- VarStore
- PchSetup
- VarStore GUID
- 4570B7F1-ADE8-4943-8DC3-406472842384
- Offset
- 0x731
- Width
- 1 byte(s)
- Range
- 0 to 3 step 0
Visibility / conditions
- {"condition_id": 1819, "type": "SuppressIf", "offset": 526000, "expr": ["EqIdVal QuestionId: 0x10F0, Value: 0x1"]}
Permalink
Determine the value of SATA Port Tinactive
- Opcode
- OneOf
- Question ID
- 0x10fc
- VarStore
- PchSetup
- VarStore GUID
- 4570B7F1-ADE8-4943-8DC3-406472842384
- Offset
- 0x732
- Width
- 1 byte(s)
- Range
- 0 to 3 step 0
Visibility / conditions
- {"condition_id": 1819, "type": "SuppressIf", "offset": 526000, "expr": ["EqIdVal QuestionId: 0x10F0, Value: 0x1"]}
Permalink